Components

Construction assembly F0159

Lignum ID-№
F0159
Catalog number
F.1.01.PB30
Source of construction assembly
PB 18-002112-PR01 PB 30-F01-04-de-01, Year 2018
Base structure
Ribs
Sheathing
Sheathed left & rightside
Paneling
Without covering
Reference fire protection
VKF Brandschutzanwendung Nr. 15421
Construction height
495 mm
Weight
280 kg/m2
U-value
≈ 0.165 W/m2K
GWP
0.00 kg CO2-eq/m2
Type sound insulation
Measurement
Flat roof / shed roof consisting of a basic construction of ribs without cavity insulation in the supporting structure. Sheathed left & rightside, leftside single sheathed rightside single sheathed. Without covering with insulation on top of the sub-floor.
Values of airborne sound insulation
Rw 57 dB
C -2 dB
Ctr -7 dB
Values of footfall sound insulation
Ln,w 40 dB
CI 0 dB
CI50-2500 dB

Graphic

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Measurement Ift Rosenheim 35 36 46 48 44 39 37 42 53 53 54 56 61 69 76 81 83 81 83 86 86
Calculation Lignum/Kühn and Blickle 13 16 18 21 24 26 28 27 30 33 36 38 41 43 44 43 44 53 61 68 77 86
Impact sound (Ln) Measurement Ift Rosenheim 63 62 52 51 46 46 46 40 33 40 42 42 35 34 25 26 16 21 16 9 9
Calculation Lignum/Kühn and Blickle 68 68 69 69 69 70 71 74 75 75 75 76 76 77 79 83 85 79 74 70 64 58

Airborne sound (R)

Loading...

Ecological indicators according to the KBOB life cycle assessment data in the construction sector KBOB / ecobau / IPB 2009/1:2022, Version 6
(For the life cycle phases production and disposal, excluding the construction phase (Modules A4, A5) and the use phase (Module B), especially replacement (Module B4) or amortization periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
130536
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
95424
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
35098
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
792.90
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
776.70
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
323.50
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
452.30
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
16.20
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
477.50
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
476.40
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
104.90
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
371.60
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.80
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
314.90
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
299.30
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
218.90
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
80.60
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
15.40
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
80.20
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
52.10
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
28.10
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
119.17
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
32.50
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)