A2140
BRESTA Solid Timber System
281
mm
R
w
58
dB
L
nw
57
dB
with floor construction
259
kg/m2
C
-3
dB
C
I
1
dB
Calculation
≈
0.301
W/m2 K
C
50-3150
-4
dB
C
I50-2500
4
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2141
BRESTA Solid Timber System
301
mm
R
w
60
dB
L
nw
55
dB
with floor construction
268
kg/m2
C
-3
dB
C
I
0
dB
Calculation
≈
0.288
W/m2 K
C
50-3150
-4
dB
C
I50-2500
4
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2142
BRESTA Solid Timber System
321
mm
R
w
61
dB
L
nw
54
dB
with floor construction
278
kg/m2
C
-3
dB
C
I
0
dB
Calculation
≈
0.276
W/m2 K
C
50-3150
-5
dB
C
I50-2500
5
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2143
BRESTA Solid Timber System
341
mm
R
w
61
dB
L
nw
54
dB
with floor construction
288
kg/m2
C
-3
dB
C
I
0
dB
Calculation
≈
0.264
W/m2 K
C
50-3150
-5
dB
C
I50-2500
5
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2144
BRESTA Solid Timber System
361
mm
R
w
62
dB
L
nw
53
dB
with floor construction
298
kg/m2
C
-3
dB
C
I
0
dB
Calculation
≈
0.254
W/m2 K
C
50-3150
-5
dB
C
I50-2500
5
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2145
BRESTA Solid Timber System
381
mm
R
w
63
dB
L
nw
52
dB
with floor construction
308
kg/m2
C
-3
dB
C
I
0
dB
Calculation
≈
0.244
W/m2 K
C
50-3150
-5
dB
C
I50-2500
5
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2146
BRESTA Solid Timber System
401
mm
R
w
63
dB
L
nw
52
dB
with floor construction
317
kg/m2
C
-3
dB
C
I
0
dB
Calculation
≈
0.236
W/m2 K
C
50-3150
-5
dB
C
I50-2500
5
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2147
BRESTA Solid Timber System
421
mm
R
w
64
dB
L
nw
51
dB
with floor construction
327
kg/m2
C
-3
dB
C
I
0
dB
Calculation
≈
0.227
W/m2 K
C
50-3150
-5
dB
C
I50-2500
5
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2148
BRESTA Solid Timber System
368
mm
R
w
73
dB
L
nw
42
dB
with floor construction
260
kg/m2
C
-6
dB
C
I
2
dB
Calculation
≈
0.218
W/m2 K
C
50-3150
-6
dB
C
I50-2500
19
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2149
BRESTA Solid Timber System
388
mm
R
w
74
dB
L
nw
41
dB
with floor construction
270
kg/m2
C
-6
dB
C
I
2
dB
Calculation
≈
0.211
W/m2 K
C
50-3150
-6
dB
C
I50-2500
19
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2150
BRESTA Solid Timber System
408
mm
R
w
74
dB
L
nw
39
dB
with floor construction
280
kg/m2
C
-6
dB
C
I
2
dB
Calculation
≈
0.204
W/m2 K
C
50-3150
-6
dB
C
I50-2500
19
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2151
BRESTA Solid Timber System
428
mm
R
w
74
dB
L
nw
38
dB
with floor construction
290
kg/m2
C
-6
dB
C
I
2
dB
Calculation
≈
0.198
W/m2 K
C
50-3150
-7
dB
C
I50-2500
19
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2152
BRESTA Solid Timber System
448
mm
R
w
74
dB
L
nw
38
dB
with floor construction
300
kg/m2
C
-6
dB
C
I
2
dB
Calculation
≈
0.192
W/m2 K
C
50-3150
-7
dB
C
I50-2500
19
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2153
BRESTA Solid Timber System
468
mm
R
w
75
dB
L
nw
37
dB
with floor construction
309
kg/m2
C
-6
dB
C
I
2
dB
Calculation
≈
0.187
W/m2 K
C
50-3150
-8
dB
C
I50-2500
19
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2154
BRESTA Solid Timber System
488
mm
R
w
75
dB
L
nw
36
dB
with floor construction
319
kg/m2
C
-6
dB
C
I
2
dB
Calculation
≈
0.181
W/m2 K
C
50-3150
-8
dB
C
I50-2500
19
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2155
BRESTA Solid Timber System
508
mm
R
w
75
dB
L
nw
36
dB
with floor construction
329
kg/m2
C
-6
dB
C
I
2
dB
Calculation
≈
0.177
W/m2 K
C
50-3150
-8
dB
C
I50-2500
19
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2156
BRESTA Solid Timber System
528
mm
R
w
75
dB
L
nw
35
dB
with floor construction
339
kg/m2
C
-6
dB
C
I
2
dB
Calculation
≈
0.172
W/m2 K
C
50-3150
-8
dB
C
I50-2500
19
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2157
BRESTA Solid Timber System
383
mm
R
w
73
dB
L
nw
40
dB
with floor construction
276
kg/m2
C
-6
dB
C
I
2
dB
Calculation
≈
0.216
W/m2 K
C
50-3150
-4
dB
C
I50-2500
19
dB
Detail
IFC4 LOD300
XLSX
A2158
BRESTA Solid Timber System
403
mm
R
w
74
dB
L
nw
39
dB
with floor construction
286
kg/m2
C
-6
dB
C
I
2
dB
Calculation
≈
0.209
W/m2 K
C
50-3150
-4
dB
C
I50-2500
19
dB
Detail
IFC4 LOD300
XLSX
A2159
BRESTA Solid Timber System
423
mm
R
w
74
dB
L
nw
38
dB
with floor construction
296
kg/m2
C
-6
dB
C
I
2
dB
Calculation
≈
0.202
W/m2 K
C
50-3150
-4
dB
C
I50-2500
19
dB
Detail
IFC4 LOD300
XLSX