E0125
Ribs / rafters
489
mm
R
w
51
dB
Insulation between and on supporting structure with covering
93
kg/m2
C
-3
dB
Verified calculation
≈
0.129
W/m2 K
C
tr
-10
dB
Detail
IFC4 LOD300
XLSX
E0130
Ribs / rafters
489
mm
R
w
52
dB
Insulation between and on supporting structure with covering
103
kg/m2
C
-3
dB
Verified calculation
≈
0.13
W/m2 K
C
tr
-9
dB
Detail
IFC4 LOD300
XLSX
E0135
Solid wood panel
419
mm
R
w
50
dB
Insulation on supporting structure
112
kg/m2
C
-2
dB
Verified calculation
≈
0.182
W/m2 K
C
tr
-7
dB
Detail
IFC4 LOD300
XLSX
E0136
Solid wood panel
474
mm
R
w
55
dB
Insulation on supporting structure with covering
125
kg/m2
C
-3
dB
Verified calculation
≈
0.151
W/m2 K
C
tr
-9
dB
Detail
IFC4 LOD300
XLSX
E0137
Solid wood panel
489
mm
R
w
57
dB
Insulation on supporting structure with covering
136
kg/m2
C
-2
dB
Verified calculation
≈
0.15
W/m2 K
C
tr
-8
dB
Detail
IFC4 LOD300
XLSX
E0139
Solid wood panel
494
mm
R
w
59
dB
Insulation on supporting structure with covering
126
kg/m2
C
-5
dB
Verified calculation
≈
0.141
W/m2 K
C
tr
-13
dB
Detail
IFC4 LOD300
XLSX
E0140
Solid wood panel
509
mm
R
w
63
dB
Insulation on supporting structure with covering
137
kg/m2
C
-4
dB
Verified calculation
≈
0.139
W/m2 K
C
tr
-11
dB
Detail
IFC4 LOD300
XLSX
E0147
BRESTA Solid Timber System, planked on one side
397
mm
R
w
36
dB
Insulation between the supporting structure
106
kg/m2
C
-1
dB
Calculation
≈
0.191
W/m2 K
C
tr
-7
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
E0148
Ribs / rafters
437
mm
R
w
37
dB
Insulation between the supporting structure
111
kg/m2
C
-1
dB
Calculation
≈
0.17
W/m2 K
C
tr
-7
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
E0149
Ribs / rafters
477
mm
R
w
38
dB
Insulation between the supporting structure
115
kg/m2
C
-1
dB
Calculation
≈
0.152
W/m2 K
C
tr
-7
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
E0150
Ribs / rafters
557
mm
R
w
39
dB
Insulation between the supporting structure
124
kg/m2
C
-1
dB
Calculation
≈
0.127
W/m2 K
C
tr
-7
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
E0151
Ribs / rafters
637
mm
R
w
40
dB
Insulation between the supporting structure
133
kg/m2
C
-1
dB
Calculation
≈
0.108
W/m2 K
C
tr
-7
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
E0152
Ribs / rafters
377
mm
R
w
49
dB
Insulation between the supporting structure
100
kg/m2
C
-1
dB
Calculation
≈
0.182
W/m2 K
C
tr
-5
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
E0153
Ribs / rafters
417
mm
R
w
51
dB
Insulation between the supporting structure
103
kg/m2
C
-1
dB
Calculation
≈
0.158
W/m2 K
C
tr
-5
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
E0154
Ribs / rafters
457
mm
R
w
52
dB
Insulation between the supporting structure
107
kg/m2
C
-1
dB
Calculation
≈
0.14
W/m2 K
C
tr
-5
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
E0155
Ribs / rafters
537
mm
R
w
54
dB
Insulation between the supporting structure
113
kg/m2
C
-1
dB
Calculation
≈
0.113
W/m2 K
C
tr
-5
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
E0156
Ribs / rafters
597
mm
R
w
56
dB
Insulation between the supporting structure
118
kg/m2
C
-1
dB
Calculation
≈
0.099
W/m2 K
C
tr
-5
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
E0157
BRESTA Solid Timber System
382
mm
R
w
49
dB
Insulation on supporting structure
119
kg/m2
C
-2
dB
Calculation
≈
0.216
W/m2 K
C
tr
-7
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
E0158
BRESTA Solid Timber System
422
mm
R
w
50
dB
Insulation on supporting structure
124
kg/m2
C
-2
dB
Calculation
≈
0.189
W/m2 K
C
tr
-7
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
E0159
BRESTA Solid Timber System
442
mm
R
w
50
dB
Insulation on supporting structure
126
kg/m2
C
-2
dB
Calculation
≈
0.177
W/m2 K
C
tr
-7
dB
Detail
IFC4 LOD300
XLSX
Test report PDF