E0160
BRESTA Solid Timber System
502
mm
R
w
51
dB
Insulation on supporting structure
133
kg/m2
C
-2
dB
Calculation
≈
0.151
W/m2 K
C
tr
-7
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
E0161
BRESTA Solid Timber System
562
mm
R
w
51
dB
Insulation on supporting structure
139
kg/m2
C
-2
dB
Calculation
≈
0.131
W/m2 K
C
tr
-7
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
E0162
Ribs / rafters
482
mm
R
w
41
dB
Insulation on supporting structure
88
kg/m2
C
-3
dB
Calculation
≈
0.192
W/m2 K
C
tr
-8
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
E0163
Ribs / rafters
522
mm
R
w
42
dB
Insulation on supporting structure
93
kg/m2
C
-3
dB
Calculation
≈
0.164
W/m2 K
C
tr
-8
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
E0164
Ribs / rafters
542
mm
R
w
43
dB
Insulation on supporting structure
96
kg/m2
C
-3
dB
Calculation
≈
0.153
W/m2 K
C
tr
-8
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
E0165
Ribs / rafters
602
mm
R
w
43
dB
Insulation on supporting structure
103
kg/m2
C
-3
dB
Calculation
≈
0.127
W/m2 K
C
tr
-8
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
E0166
Ribs / rafters
662
mm
R
w
44
dB
Insulation on supporting structure
110
kg/m2
C
-3
dB
Calculation
≈
0.108
W/m2 K
C
tr
-8
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
E0167
Ribs / rafters
504
mm
R
w
50
dB
Insulation on supporting structure
91
kg/m2
C
-1
dB
Calculation
≈
0.189
W/m2 K
C
tr
-5
dB
Detail
IFC4 LOD300
XLSX
E0168
Ribs / rafters
544
mm
R
w
51
dB
Insulation on supporting structure
96
kg/m2
C
-1
dB
Calculation
≈
0.162
W/m2 K
C
tr
-6
dB
Detail
IFC4 LOD300
XLSX
E0169
Ribs / rafters
584
mm
R
w
51
dB
Insulation on supporting structure
100
kg/m2
C
-1
dB
Calculation
≈
0.142
W/m2 K
C
tr
-5
dB
Detail
IFC4 LOD300
XLSX
E0170
Ribs / rafters
644
mm
R
w
51
dB
Insulation on supporting structure
108
kg/m2
C
-1
dB
Calculation
≈
0.119
W/m2 K
C
tr
-5
dB
Detail
IFC4 LOD300
XLSX
E0171
Ribs / rafters
704
mm
R
w
52
dB
Insulation on supporting structure
115
kg/m2
C
-1
dB
Calculation
≈
0.103
W/m2 K
C
tr
-5
dB
Detail
IFC4 LOD300
XLSX
E0172
Ribs / rafters
502
mm
R
w
51
dB
Insulation on supporting structure
89
kg/m2
C
-1
dB
Calculation
≈
0.215
W/m2 K
C
tr
-5
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
E0173
Ribs / rafters
542
mm
R
w
51
dB
Insulation on supporting structure
93
kg/m2
C
-1
dB
Calculation
≈
0.188
W/m2 K
C
tr
-5
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
E0174
Ribs / rafters
562
mm
R
w
52
dB
Insulation on supporting structure
96
kg/m2
C
-1
dB
Calculation
≈
0.177
W/m2 K
C
tr
-6
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
E0175
Ribs / rafters
622
mm
R
w
52
dB
Insulation on supporting structure
102
kg/m2
C
-1
dB
Calculation
≈
0.15
W/m2 K
C
tr
-5
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
E0176
Ribs / rafters
682
mm
R
w
53
dB
Insulation on supporting structure
109
kg/m2
C
-1
dB
Calculation
≈
0.131
W/m2 K
C
tr
-5
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
E0177
Ribs / rafters
398
mm
R
w
49
dB
Insulation between the supporting structure of covering
97
kg/m2
C
-5
dB
Calculation
≈
0.198
W/m2 K
C
tr
-11
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
E0178
Ribs / rafters
458
mm
R
w
50
dB
Insulation between the supporting structure of covering
105
kg/m2
C
-5
dB
Calculation
≈
0.166
W/m2 K
C
tr
-11
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
E0179
Ribs / rafters
498
mm
R
w
50
dB
Insulation between the supporting structure of covering
110
kg/m2
C
-5
dB
Calculation
≈
0.15
W/m2 K
C
tr
-11
dB
Detail
IFC4 LOD300
XLSX
Test report PDF